NI-FGEN 2.6 - Windows 2000/Vista x64/Vista x86/XP
2
評分 | 3.00 之 5
列印檔案
可進行的下載作業:
所支援的檔案:
下載語言: 英語
產品線: Signal Generators
版本: 2.6
發表日期:
07-2008
軟體種類: Hardware Driver
作業系統: Windows 2000; Windows Vista x64; Windows Vista x86; Windows XP
說明
NI-FGEN 2.6 includes the following new features:
- Support for the NI PXIe–5450 Dual-Channel I/Q Generator with Onboard Signal Processing (OSP)
- Improved scaled write (DBL) performance
- A number of new VIs, properties, functions, and attributes
Supported Hardware
The following table shows which hardware products are supported in this release under particular operating systems.
| Hardware Product |
Supported Under Windows 2000 |
Supported Under Windows XP |
Supported Under Windows Vista |
| NI PXI/PCI-5401 Function Generator |
√ |
√ |
X |
| NI PXI/PCI-5402 Function Generator |
√ |
√ |
√ |
| NI PXI-5404 Frequency Generator |
√ |
√ |
√1 |
| NI PXI/PCI-5406 Function Generator |
√ |
√ |
√ |
| NI PXI/PCI-5411 Arbitrary Waveform Generator |
√ |
√ |
X |
| NI PXI/PCI-5412 Arbitrary Waveform Generator |
√ |
√ |
√ |
| NI PXI/PCI-5421 Arbitrary Waveform Generator |
√ |
√ |
√ |
| NI PXI-5422 Arbitrary Waveform Generator |
√ |
√ |
√ |
| NI PXI/PCI-5431 Video Signal Generator |
√ |
√ |
X |
| NI PXI-5441 Arbitrary Waveform Generator with Onboard Signal Processing |
√ |
√ |
√ |
| NI PXIe–5442 Arbitrary Waveform Generator with Onboard Signal Processing |
X |
√ |
√ |
| NI PXIe–5450 Dual-Channel I/Q Generator with Onboard Signal Processing |
X |
√ |
√ |
| 1 Windows Vista support for the NI 5404 does not include support for external calibration. External calibration for the NI 5404 should be performed on Windows XP or Windows 2000. |
Application Development Software
- NI LabVIEW 7.1.1, 8.2.1, 8.5.1, or 8.6
- NI LabVIEW Real-Time Module 7.1.1, 8.2.1, 8.5.1, or 8.6 (no support for NI PXI/PCI-5401/5411/5431 devices)
- LabWindows ™ /CVI ™ 7.1.1 or later
- LabWindows ™ /CVI ™ Real-Time Module (no support for NI PXI/PCI-5401/5411/5431 devices)
Note: If you are running your application on an RT target, at least 128 MB of memory is required.
- Measurement Studio 6.0, 7.0, 7.1, 8.0, 8.1, or 8.5
- Microsoft Visual C++ (MSVC) 6.0 or later
- Microsoft Visual Basic 6.0
安裝說明
NI-FGEN Installation Instructions:
1. Create a temporary folder on your local hard drive.
2. Extract the NI-FGEN_2_6.zip file into the folder created in Step 1. This creates the installation files necessary for installing NI-FGEN.
3. To launch the NI-FGEN installer, run the \NIFGEN 2.6\NIFGEN260\autorun.exe program extracted in step 1